Rhino Plug
Single-Pole High-Current Connector

Fast Connection for Temporary Power Distribution
Rhino plug single-pole connectors are designed for temporary and repeat-use power systems, where cables need to be connected, removed and reconfigured faster than permanent hardwiring.
Faster Than Hardwiring
Helps reduce wiring time during temporary setup, maintenance and field power connection.
Spring-Assisted Twist-Lock
Insert and rotate to lock. The safety latch prevents unintended reverse rotation, while the internal spring helps make disconnection easier after unlocking.
Quick System Reconfiguration
Helps technicians move and reconnect power lines more efficiently during temporary system changes after power is isolated.
Easier Field Maintenance
Makes cable inspection, replacement and maintenance easier than fixed hardwired connections.
Important Operation Note
This connector is intended for connection and disconnection without load. Isolate the power before plugging or unplugging. Install within a supplementary enclosure in the end application or in a restricted-access area. The final installation must provide protection against electric shock and secure the terminations against pull and twisting.
Complete 400A Rhino Plug Set for L1 / L2 / L3 / N / PE
This page focuses on one 400A Rhino plug connector set. A complete set includes five color-coded single-pole connectors for L1, L2, L3, neutral and earth connection in temporary power distribution systems.
What Is Included in One Set?
Each line uses one single-pole connector. The color-coded design helps installers identify phase, neutral and earth connections more clearly during field installation and maintenance.

Documented Performance.
Clear Technical Specifications.
Review the LVD Certificate of Conformity and supporting type-test report for the listed SF400A connector models. Use the model and cable configuration to select the applicable documentation for your project.
Technical Specifications
| Product | 400A Rhino single-pole connector range |
|---|---|
| Connection options | Cable-mounted plugs and connectors; panel-mounted versions |
| Line identification | L1 Brown · L2 Black · L3 Grey · N Blue · PE Green |
| Rated current | 400A |
| Rated voltage | 1000V AC/DC |
| IP rating | IP67 after correct installation and full engagement |
| Cable-mounted conductor size | 120 mm² — supplied product specification |
| Panel-mounted conductor size | 240 mm² — supplied product specification |
| Cable gland range | 22–32 mm for cable-mounted versions |
| Ambient temperature | −25°C to +40°C |
| Product temperature limits | −25°C to +85°C |
| Housing material | PA6 |
| Contact material | Tin-plated copper alloy |
| TÜV test standards | IEC 61984:2008 / EN 61984:2009 |
Test-report configuration
Report CN26GPM7 001 records testing with 240 mm² conductors, including the cable-mounted pair. For the supplied 120 mm² cable-mounted configuration, request confirmation of the applicable test documentation before ordering.
LVD Certificate of Conformity
- Certificate No.
- AN 50750013 0001
- Directive
- Low Voltage Directive 2014/35/EU
- Issued
- 2 November 2026
- Certificate holder
- Wenzhou Shangfeng Electric Co., Ltd.
- Model families
- SF400A-MT / GT / MZ / GZ, with listed L1 / L2 / L3 / N / PE variants
The certificate identifies the covered models and references the supporting test report. View the original certificate using the link below and request the full test report for procurement and project technical review.
The certificate is based on sample evaluation. Model scope, test conditions and installation requirements apply as stated in the original documents.
Test Report CN26GPM7 001
Issued by TÜV Rheinland/CCIC (Ningbo) Co., Ltd. on 28 October 2026, to IEC 61984:2008 and EN 61984:2009.
- 400A temperature-rise testing with the 240 mm² conductor configuration recorded in the report.
- 500 mechanical operation cycles; the connectors have no breaking capacity and must be connected or disconnected without load.
- IP67 testing for correctly installed and engaged connectors.
- Material evaluation includes 850°C glow-wire testing; individual component conditions are listed in the report.
These are highlights of the type-test programme for the configurations assessed in the report, rather than a statement that every model underwent every individual test.
View the certificate directly. To request the full test report, include your required model, cable size and application.
Where the Rhino Plug Set Is Used
The Rhino plug set is used in temporary power systems where cables are moved, connected and reconfigured more often than permanent fixed wiring.
Temporary Distribution Boxes
Used on temporary power boxes where incoming and outgoing power lines need clear, serviceable connection points.
Generator Connection
Suitable for temporary generator supply, standby power connection, field testing and maintenance projects.
Stage Lighting and Event Power
Used in event power systems where cables may be repeatedly installed, removed and checked between projects.
Industrial Field Power
Useful for maintenance sites, mobile equipment, construction areas and temporary industrial power connections.

Send Details for Fast Quotation
To check whether the 400A Rhino plug set is suitable for your project, please send the following details before quotation.
What to Send Us
Cable Size
Send your conductor size and cable outer diameter so we can check whether the connector is suitable.
Application
Tell us whether it will be used for a generator, temporary distribution box, event power or field power system.
Existing Connector Photos
For replacement or matching, send front, side and label photos of your current connector.
Quantity Requirement
Confirm whether you need complete five-line sets or specific replacement pieces.
Request a Quote & Technical Documents
Send your required model, cable size and application. We will help check the connector configuration and provide the relevant certificate and test report for review.
Frequently Asked Questions About Rhino Plug
Common questions about the 400A Rhino plug set, spring-assisted twist-lock structure, certification, cable connection and project matching.
What is a Rhino plug used for?
A Rhino plug is a single-pole high-current connector used in temporary power systems, such as generator connection, temporary distribution boxes, stage power and industrial field power.
Is this product a complete set or a single connector?
This product page focuses on a 400A five-color set. One complete set includes single-pole connectors for L1, L2, L3, N and PE.
What current rating is available?
The current product on this page is the 400A Rhino plug set. If you need other current ratings, please confirm with us before ordering.
Which colors correspond to L1, L2, L3, N and PE?
The five-color set uses L1 brown, L2 black, L3 grey, N blue and PE green. This helps installers identify phase, neutral and earth lines more clearly.
How does the spring-assisted twist-lock mechanism work?
The Rhino plug connector pair uses a spring-assisted twist-lock structure with a black safety latch. During connection, the plug is inserted into the socket, the internal spring is compressed, and the connector is rotated into the locked position. The black safety latch helps prevent unintended reverse rotation during use. To disconnect, release the latch first, rotate the connector back to the unlocked position, and then pull it out. The compressed spring provides outward force, helping make removal easier than conventional high-current plug and socket connections.
What cable size does it support?
Cable-mounted plugs and connectors are supplied for 120 mm² conductors; panel-mounted versions are supplied for 240 mm² conductors. Report CN26GPM7 001 records a 240 mm² test configuration. Confirm the applicable documentation for your selected model and cable size before ordering.
Is the Rhino plug suitable for outdoor use?
The IP67 rating applies after correct installation and full engagement. The test report specifies use within a supplementary enclosure in the end application or in a restricted-access area. Confirm the installation, cable gland condition and operating environment for your project.
Can it be connected or disconnected under load?
No. This is a connector without breaking capacity. Isolate the power before connection or disconnection. The 500-cycle mechanical test must not be described as a load-breaking endurance rating.
What TÜV Rheinland documents are available?
The TÜV Rheinland LVD Certificate of Conformity AN 50750013 0001 is available to view here. Supporting test report CN26GPM7 001, referencing IEC 61984:2008 and EN 61984:2009, is available on request for the listed SF400A connector models. Contact us to confirm your model and cable configuration.
Can you help check compatibility with my existing connector?
Yes. Please send clear front, side and label photos of your existing connector, together with cable size, application and required quantity. We will help check the suitable matching option before quotation.