INDUSTRIAL SOCKETS · IEC 60309
Industrial Panel Mounted Sockets (Flush Type)
Panel-mounted female sockets for distribution boxes, control panels and equipment enclosures. Choose the model that matches your electrical requirements and panel installation.
- 16A · 32A · 63A · 125A
- 3-pin · 4-pin · 5-pin
- IP44 / IP67 options
Compare Standard, Pro and Premium models by voltage, poles and IP rating. Check the model numbers and panel cut-out dimensions below; available combinations vary by model.
GET A QUOTENeed help choosing the mounting type? Read our industrial plug and socket types guide.


Series

Series
Official Lab Test Summary
Certified by CNAS & ILAC-MRA (Global Mutual Recognition).
Based on the 94-page official CQC testing report for SFE Industrial Plugs.
| Test Item | IEC Safety Standard | SFE Actual Result | Status |
|---|---|---|---|
| 🔥 Fire Safety (Glow-Wire Test) | Must pass 850°C heat | 0s Ignition (Self-extinguishing) | ✔ PASSED |
| ⚡ Thermal Stability (Temp Rise Test) | Max 50K at full load | Stable (< 50K). No melting. | ✔ PASSED |
| 🛡️ Earthing Safety (Grounding Test) | Resistance ≤ 0.05 Ω | ≤ 0.05 Ω (Instant fault clearing) | ✔ PASSED |
| 🔌 Insulation Safety (Dielectric Strength) | No breakdown under high voltage | Zero Breakdown. 100% safe. | ✔ PASSED |
| 💧 Weather Protection (IP Rating Test) | Water & Dust proof | Perfect Sealing for outdoor use. | ✔ PASSED |

Economic Series
Standard PP or Nylon material. Ideal for indoor workshops and budget-sensitive projects. Reliable performance at best price.

New Series (Shark)
Ergonomic grip design with upgraded PA6 material. Better handling and durability for general industrial use.

High-End Series
Virgin PA66 + Solid Brass. Designed for mining, petrochemical, and extreme harsh environments.
● Fast Reply within 1 Hour ● Factory Direct Price
In-House Quality Control
We don't guess; we test. Every SFE industrial plug and socket is rigorously engineered and validated in our own laboratory to guarantee absolute IEC 60309 compliance.

Temperature Rise Test
Monitors heat generation under continuous full load to guarantee the temperature stays well below the IEC 50K safety limit. Zero risk of melting.

850°C Glow-Wire Testing
Ensures our PA66 plastic carriers are strictly self-extinguishing (0s ignition) and fully fire-proof under extreme electrical short-circuit faults.

Hi-Pot / Dielectric Test
Verifies extreme insulation strength. We apply high voltage surges to ensure zero dielectric breakdown, preventing electric shock hazards in harsh environments.

IP44/IP67 Waterproof Test
Simulates extreme weather conditions, from heavy splashing to high-pressure water jets, ensuring absolute waterproof integrity for outdoor applications.

Pendulum Impact Test
Applies concentrated kinetic strikes to the housing surface to verify extreme mechanical impact resistance, critical for heavy industry and mining operations.

Extreme Weather Simulation
From -30°C freezing cold to +80°C scorching heat. We cycle our products through extreme temperature chambers to guarantee reliable performance globally.
STANDARD · PRO · PREMIUM · FIXED FEMALE SOCKET OUTLETS
16A–125A Panel Mounted Sockets: Models & Cut-out Dimensions
Select a current rating, then compare 3-pin, 4-pin and 5-pin straight panel mounted sockets by model, voltage and IP rating. Check the panel cut-out and fixing-hole centres when planning an installation or replacement.
Standard is named Classic Series in the catalogue. The selected models below use the 6h earth position.
16A Panel Mounted Socket Models
3-pin · 2P+E
220–240V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | SF-313 | — |
| Pro | SFN-313 | SFN-3132 |
| Premium | SFK-1366 | SFK-218 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø55 | 56 × 56 4 × Ø5 holes |
| Pro | Ø50 | 61 × 61 4 × Ø5 holes |
| Premium | Ø45 | 60 × 60 4 × Ø5 holes |
4-pin · 3P+E
380–415V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | SF-314 | — |
| Pro | SFN-314 | SFN-3142 |
| Premium | SFK-1390 | SFK-222 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø55 | 56 × 56 4 × Ø5 holes |
| Pro | Ø50 | 61 × 61 4 × Ø5 holes |
| Premium | Ø52 | 60 × 60 4 × Ø5 holes |
5-pin · 3P+N+E
220–380V / 240–415V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | SF-315 | — |
| Pro | SFN-315 | SFN-3152 |
| Premium | SFK-1385 | SFK-228 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø55 | 56 × 56 4 × Ø5 holes |
| Pro | Ø55 | 61 × 61 4 × Ø5 holes |
| Premium | Ø55 | 60 × 60 4 × Ø5 holes |
32A Panel Mounted Socket Models
3-pin · 2P+E
220–240V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | SF-323 | — |
| Pro | SFN-323 | SFN-3232 |
| Premium | SFK-1395 | SFK-230 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø55 | 56 × 56 4 × Ø5 holes |
| Pro | Ø55 | 61 × 61 4 × Ø5 holes |
| Premium | Ø58 | 60 × 60 4 × Ø5 holes |
4-pin · 3P+E
380–415V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | SF-324 | — |
| Pro | SFN-324 | SFN-3242 |
| Premium | SFK-1399 | SFK-234 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø55 | 56 × 56 4 × Ø5 holes |
| Pro | Ø55 | 61 × 61 4 × Ø5 holes |
| Premium | Ø58 | 60 × 60 4 × Ø5 holes |
5-pin · 3P+N+E
220–380V / 240–415V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | SF-325 | — |
| Pro | SFN-325 | SFN-3252 |
| Premium | SFK-3451 | SFK-240 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø55 | 56 × 56 4 × Ø5 holes |
| Pro | Ø60 | 61 × 61 4 × Ø5 holes |
| Premium | Ø62 | 60 × 60 4 × Ø5 holes |
63A Panel Mounted Socket Models
3-pin · 2P+E
220–240V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | — | SF-333 |
| Pro | — | SFN-3332 |
| Premium | SFK-1261 | SFK-1264 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø75 | 80 × 80 4 × Ø7 holes |
| Pro | Ø80 | 81 × 81 4 × Ø7 holes |
| Premium | Ø89 | 78 × 86 4 × Ø7 holes |
4-pin · 3P+E
380–415V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | — | SF-334 |
| Pro | — | SFN-3342 |
| Premium | SFK-1248 | SFK-1124 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø75 | 80 × 80 4 × Ø7 holes |
| Pro | Ø80 | 81 × 81 4 × Ø7 holes |
| Premium | Ø89 | 78 × 86 4 × Ø7 holes |
5-pin · 3P+N+E
220–380V / 240–415V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | — | SF-335 |
| Pro | — | SFN-3352 |
| Premium | SFK-1252 | SFK-1128 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø75 | 80 × 80 4 × Ø7 holes |
| Pro | Ø80 | 81 × 81 4 × Ø7 holes |
| Premium | Ø89 | 78 × 86 4 × Ø7 holes |
125A Panel Mounted Socket Models
3-pin · 2P+E
220–240V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | — | SF-343 |
| Pro | — | SFN-3432 |
| Premium | — | SFK-3380 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø90 | 101 × 101 4 × Ø7 holes |
| Pro | Ø100 | 102 × 102 4 × Ø7 holes |
| Premium | Ø95 | 104 × 104 4 holes · diameter to confirm |
4-pin · 3P+E
380–415V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | — | SF-344 |
| Pro | — | SFN-3442 |
| Premium | — | SFK-1457 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø90 | 101 × 101 4 × Ø7 holes |
| Pro | Ø100 | 102 × 102 4 × Ø7 holes |
| Premium | Ø95 | 104 × 104 4 holes · diameter to confirm |
5-pin · 3P+N+E
220–380V / 240–415V AC · 6h
| Series | IP44 | IP67 |
|---|---|---|
| Standard | — | SF-345 |
| Pro | — | SFN-3452 |
| Premium | — | SFK-1461 |
Panel drilling · mm
| Series | Cut-out D | Centres A × B |
|---|---|---|
| Standard | Ø90 | 101 × 101 4 × Ø7 holes |
| Pro | Ø100 | 102 × 102 4 × Ø7 holes |
| Premium | Ø95 | 104 × 104 4 holes · diameter to confirm |
How to read the panel drilling dimensions
D: Diameter of the central panel cut-out.
A × B: Horizontal × vertical fixing-hole centre distances.
C: Diameter of each of the four fixing holes.
All dimensions are in millimetres. Confirm the model-specific drawing, panel thickness and rear clearance before fabrication. These values do not describe the flange's outside dimensions.
A dash means an option is not listed in this selection. Confirm the fixing-hole diameter for Premium 125A models before drilling. For an angled outlet, see our angled panel mounted sockets.
For a quotation or installation drawing: Send the model number and quantity for each item. For replacement orders, include a photo, existing panel cut-out, fixing-hole centres and the mating plug details so the fit and connection can be checked.
Looking for Technical Specs & Wiring Diagrams?
We have moved our detailed technical documentation—including IEC 60309 Color Codes, Clock Positions, and IP Rating Guides—to a dedicated page.
📖 Read The Ultimate Guide (2026)